IJ14 INTERMEDIATE JUNCTION REFERENCE ELECTRODE
The IJ14 – Intermediate Junction Ag/AgCl reference electrode suited for use with a wide variety of indicator electrodes such as PH, ISE and metal half-cells. The double junction design allows the user to select electrolytes suitable for use with the majority of ion selective electrode half-cells. Suitable electrolytes commonly used include KCl, KNO3, NH4NO3, and ethanolicLiCl. The IJ14 can also be used to monitor potentials of various processes such as corrosion

IJAU INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE GOLD SENSOR ORP ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 – 60°C |
ORP Range: | ±2000mV |
ORP Sensor: | Gold |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Notes: | General purpose ORP electrode |
Dimensions: | 12mm x 120mm |

IJ64 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE PLATINUM SENSOR ORP ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 – 60°C |
ORP Range: | ±2000mV |
ORP Sensor: | Platinum |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Notes: | General purpose ORP electrode |
Dimensions: | 12mm x 120mm |

IJ64HT INTERMEDIATE JUNCTION KYNAR BODY REFILLABLE PLATINUM SENSOR ORP ELECTRODE
Body: | Kynar |
Temp Range: | 0 – 100°C |
ORP Range: | ±2000mV |
ORP Sensor: | Platinum |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Notes: | General purpose high Temp ORP electrode |
Dimensions: | 12mm x 120mm |

IJ40 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE BULLET SENSOR PH ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 -60°C |
PH Range: | 0 -14 PH |
PH Sensor: | A / C Glass Bullet |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |

IJ44 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE SPEAR SENSOR PH ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 -60°C |
PH Range: | 0 -14 PH |
PH Sensor: | A / C Glass Spear |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |

IJ46 INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE FLAT SENSOR PH ELECTRODE
Body: | Polypropylene |
Temp Range: | 0 -60°C |
PH Range: | 0 -12 PH |
PH Sensor: | A / C Glass Spear |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |

IJ44HT INTERMEDIATE JUNCTION KYNAR BODY REFILLABLE SPEAR SENSOR PH ELECTRODE
Body: | KYNAR / PVDF |
Temp Range: | 0 -60°C |
PH Range: | 0 -14 PH |
PH Sensor: | A / C Glass Spear |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Cable Length: | 1m. Standard (20m Max) |
Dimensions: | 12mm x 120mm |
Connector: | BNC Standard |

IJ-Ag INTERMEDIATE JUNCTION POLYPROPYLENE BODY REFILLABLE SILVER BILLET SENSOR ELECTRODE FOR ARGENTIMETRIC TITRATION
Body: | Polypropylene |
Range: | ±2000Mv |
Range: | 0 -14 PH |
PH Sensor: | Silver |
Reference: | Double Junction Ag/AgCl/Sat KCl Gel |
Reference: | Double Junction Ag/AgCl/User Selectable Electrolyte |
Cable Length: | 1m. Standard (Max. 20m) |
Connector: | BNC Standard |
Note: | For argentimetric titration using silver nitrate or similar |